The risk of hydrogen atomic clock is assessed based on fuzzy fault tree analysis. The method of hydrogen clock fault tree building is discussed in detail based on collecting the fault of hydrogen clock system. In addition the base events resulting in fault is described by fuzzy method. The risk for hydrogen clock fault can be assessed and the weakness port can found by calculating and compositing the importance of clock fault and every base event probability, which provides the theory bases for constituting the measure of improving reliability.